Product Overview
The JSG-03WB is a 12V brushless DC diaphragm water pump for water transfer in compact OEM equipment. It delivers up to 500 mL/min and can draw water from a reservoir below the pump through a self-priming inlet.
The pump measures 64 × 49 × 30.4 mm and weighs 120 g. Its nylon pump head and body, EPDM diaphragm and EPDM valves form the liquid-handling assembly.
Typical applications include reservoir refill, instrument rinsing and clear-water drainage. For timed delivery, select the pump according to the volume required at the outlet during one complete equipment cycle.
Core Selling Points of the 12V Diaphragm Water Pump
- 500 mL/min Maximum Water Flow– Suitable for transferring water between a supply tank and a working reservoir in compact equipment.
- Self-Priming Design– The pump can draw water into an empty inlet line and develops up to −30 kPa of inlet vacuum.
- Brushless DC Motor– Expected service life is approximately 5,000 hours at 12V and 25°C, with each uninterrupted run limited to two hours.
- Compact 64 mm Body– The 120 g pump fits inside benchtop instruments and removable water-handling modules where mounting space is limited.
- 50 dB at 30 cm– The specified measurement distance gives engineers a reference for checking noise after mounting the pump inside the enclosure.
What Are the Key Specifications of This 12V Diaphragm Water Pump?
| Item | Specification |
| Product model | JSG-03WB |
| Pump type | Self-priming micro diaphragm water pump |
| Motor type | Brushless DC motor |
| Rated voltage | 12V DC |
| Maximum water flow | 500 mL/min |
| Maximum inlet vacuum | −30 kPa |
| No-load current | ≤0.4 A |
| Noise level | 50 dB measured at 30 cm |
| Reference medium | Water |
| Pump head and body | Nylon |
| Diaphragm and valves | EPDM |
| Operating ambient temperature | 5–45°C |
| Working mode | Continuous or intermittent, up to 2 hours per run |
| Expected service life | Approx. 5,000 hours at 12V and 25°C, subject to the run limit above |
| Pump dimensions | 64 × 49 × 30.4 mm |
| Weight | 120 g |
What Are the Dimensions and Installation Details?
The JSG-03WB has a 64 mm body length, 49 mm height and 30.4 mm width. Allow space beyond the pump body for the tubing bends and power leads.

Which Media Is This Diaphragm Water Pump Compatible With?
Water is the reference medium for the JSG-03WB flow specification. For other liquids, compatibility depends on how the formulation interacts with the nylon pump head, EPDM diaphragm and EPDM valves.
| Medium | Recommendation |
| Clean water | Recommended for standard water-transfer applications. |
| Water with particles | Review particle size and filtration requirements before testing. |
| Water-based cleaning solution | Provide the formulation, concentration and liquid temperature for material review. |
| Warm water | Confirm the intended liquid temperature with JSG. The published 5–45°C range applies to ambient air. |
What Applications Is This DC Liquid Pump Suitable For?
- Reservoir Refill Systems
The JSG-03WB can draw water from a removable supply tank and refill a working reservoir. Its self-priming design is useful when changing the tank allows air into the inlet line. Check refill time at the lowest expected tank level.
- Rinse Cycles in Benchtop Instruments
A 12V instrument can use the pump to deliver water to a rinse chamber or wash outlet. For a timed rinse, measure the volume at the final outlet with the production tubing and fittings installed.
- Clear-Water Drainage Modules
The pump can transfer clear water from a collection tray to a receiving bottle. When the tray empties between cycles, check how quickly water reaches the bottle after the next start.
How Do I Choose the Right DC Diaphragm Water Pump?
If your equipment uses a 12V power supply
Select the JSG-03WB for a nominal 12V DC system. The ≤0.4 A rating applies at no load. Use measured startup and loaded running current to size the power supply.
If you need a specific volume per cycle
Divide the required volume by the available delivery time to find the target flow. Verify it with the actual tubing, outlet height and downstream restrictions. The 500 mL/min figure is the maximum water flow.
If the reservoir sits below the pump
Measure the vertical distance from the lowest water level to the inlet. Test priming from that level with the inlet line drained, especially if your equipment must deliver water immediately after startup.
If the pump runs for extended periods
Check the longest uninterrupted run in your operating schedule. The JSG-03WB specification allows up to two hours per run. For longer cycles, send the duty schedule to JSG for model selection.
OEM Project Examples Using This DC Liquid Pump
- Benchtop Rinse Station
An instrument that requires 100 mL in 20 seconds needs an average outlet flow of 300 mL/min. To evaluate the JSG-03WB, fit the intended rinse outlet and collect the discharge for 20 seconds. The measured volume shows whether the pump meets the rinse requirement at the installed working point.
- Water Module with a Removable Tank
A tank change can leave the inlet line empty even when the new tank is full. For this layout, test the first fill cycle immediately after replacing the tank. Record the time to first water and the total refill time to determine whether the equipment needs a separate priming interval.
Files and Technical Documents
Why Work With JSG DC PUMP as Your OEM Pump Supplier?
- Engineering support– Our team can review your required flow, suction lift, outlet pressure and duty cycle to help select a pump for your equipment.
- Sample evaluation– Test the JSG-03WB with your own reservoir, tubing and outlet assembly before confirming the production configuration.
- Installation support– We can review mounting clearance, tubing connections and optional accessories such as a check valve or silicone shock bracket. JSG DC PUMP
For samples or an OEM quotation, send your required water volume per cycle, delivery time, inlet and outlet heights, and expected quantity to admin@dc-pump.com.